Easycore
Multi-bar Temperature Measurement System
A unique solution that meets stringent regulations
in the measurement of critical temperature points during thermal processing of food products.

Innovative system functions
-
Freedom of use – compatible data transfer system
-
Possibility to use multiple sensors
-
Freedom to place the sensor in the machine space
-
Freedom of use in systems with forced movement of smoking trolleys - pass-through chambers, rotary kilns
The EASYCORE R radio transmitter converts measurements from many sensors into one output signal, which is connected to the measuring system of existing or newly installed industrial automation devices. Wireless data transmission means unlimited possibilities of deploying many sensors at any point in the machine. Advantages of the system - freedom of use, intuitive operation, easy installation, compatibility with other devices.
Technical parameters
WL-120 temperature sensor
- Body ambient temperature-30 / + 130 ° C
- Measurement range-30 / + 130 ° C
- Measurement accuracy≤0,5°C
- Measurement resolution0.1°C
- Level of securityP20
- CompositionApproved for contact with food
- Probe typePT-1000 (replaceable)
- The output signal2.4 GHz radio signal
- Power3.6V lithium battery
Easycore R temperature transmitter
- Body ambient temperature-20 / + 60 ° C
- Number of exitsFrom 1 to 4 depending on the transducer type
- outputsConfigurable 0/20 mA
PT-100 emulation (optional) - Input signal2.4 GHz radio signal
- Power24V DC
- display0,96 ″ OLED
- Sensorup to 32 WL-120 sensors
The EASY CORE C 400 cable transducer converts measurements from multiple sensors into one output signal, which is connected to the measuring system of existing or newly installed industrial automation devices. Advantages of the system - intuitive operation, easy installation, compatibility with other devices.
Technical parameters
functionality
- temperature measurement range -99,9°C ÷ 500,0°C
- temperature measurement resolution 0,1°C
- ≤ ±0,5 °C (depending on the class of the measuring probe used)
- calculating the average, max, min current values of a group of sensors
- ALARM output configuration: no sensor, max, min
- AO output configuration: single sensor, sensor group (average value, min, max)
- registration memory
- RTC clock
Easy Core C 400 Temperature Transmitter
- EntrancesAnalog AI: 4x PT100 (3-wire) / thermocouples K,J;
Digital DI: 1x 24V DC - outputsAnalog, current: 1x 0 ÷ 20 mA/4 ÷ 20 mA;
Two-state: 1x 24 V DC (ALARM, active 0/24 VDC) - Power24VDC ±10%
- Temperature measuring range99,9 ÷ 500,0 ° C
- Level of securityIP20
- display0,96 ″ OLED