Microprocessor controllers MCC-026 – intended for automatic control of industrial devices requiring programmatic operation and measurement of physical quantities, e.g. temperature, humidity, etc. In particular, the controller is intended to control the technological process in drying chambers.
industrial structure with increased resistance to external conditions and mechanical damage
possibility of installation in "blind" holes (from the front)
very small installation depth
click keys
clear LED displays
internal process registration memory
work in the MPC4 system
ready-made solution without the need to create firmware
Technical parameters
MCC 026 controller
General Information
Power
24 VAC
Power consumption
10 W
Physical parameters
dimensions
Mounting hole dimensions: 143×238 mm
Installation depth with connections: 48 mm
External dimensions of the frame with seal: 187x280mm
Weight
Driver: 1250 g
Transformer: 800 g
design
display
LED 0,8'' x 4 digits LED 0,8'' x 2 digits
LED 0,8'' x 2 digits LED 0,8'' x 2 digits
LED 0,8'' x 2 digits LED 0,8'' x 2 digits
Housing
One-piece Front Panel
Features
Level of security
From the connections side: IP 20
From the front: IP 65
Real-time clock
Yes
Temperature measuring range
-30.. +400 °C (resolution 0.1 °C)
Digital communication
1x RS 485 – communication with a PC
1x RS232
Regulator type
No
Keyboard
28 "CLICK SWITCH" keys
Recording of measurements
2000 samples, registration of set and measured values
startup
Yes, according to RTC with the possibility of programming the controller's activation up to 24 hours in advance
Other
Conditional program execution depending on humidity
Program control of executive devices (contactors, solenoid valves, etc.)
Manual operation mode
Programs
50 (0..49) technological programs, freely changeable by the user, automatic chamber washing program (99)
Moisture measurement
Humidity control and regulation 0-99%
Software
Software
MPC3
Inputs / outputs
Entrances
Analog inputs: 3
Analog input type
2x PT 100 temperature sensor (dry. wet)
Temperature measurement range: -30 .. 400 °C
Accuracy: 0,1 °C
Humidity measurement range: 0..99%
Accuracy: 1%
Current input 4..20 mA (humidity sensor)
Digital input: 1
DUAL-STATE INPUT TYPE:
0-220VAC (0-24VAC)
Optoinsulation
outputs
Relay outputs: 8
(Relay output type: Normally Open 250V
Total current of connected relays: Iomax = 5A)
Operating mode
Working conditions
Operating temperature 0 °C .. +60 °C
Storage temperature -20 °C .. +70 °C
Humidity: 0..75%