PARP

MCC-051 microprocessor controllers are devices used in the automatic control of SMOKING AND SCALDING CHAMBERS as well as STEAM CURING BOILERS in the meat industry.

The controllers are also used to control other industrial devices requiring programmed operation and measurement of physical quantities, such as temperature, pressure, etc.

Intended use:
  • smoking and scalding chambers
  • ripening chambers
  • climatic chambers

    Technical specifications

    POWER SUPPLY:

    • 24 VAC

    POWER CONSUMPTION:

    • 10 W

    DIMENSIONS:

    • Mounting hole dimensions: 143x238 mm
    • Installation depth with connections: 47 mm
    • External dimensions of the frame with seal: 187x280 mm

    DISPLAY:

    • LED 0.8’’ x 4 digits LED 0.8’’ x 4 digits
    • LED 0.8’’ x 3 digits LED 0.8’’ x 3 digits
    • LED 0.8’’ x 3 digits LED 0.8’’ x 3 digits
    • LED ½’’ x 3 digits

    WEIGHT:

    • Controller: 1250 g
    • Transformer: 800 g

    ENCLOSURE:

    • Monolithic type Front Panel

    PROTECTION RATING:

    • From the connections’ side: IP 20
    • From the front: IP 65

    TEMPERATURE MEASUREMENT RANGE:

    • -50.. +400 °C (resolution 0.1 °C)

    OPERATING CONDITIONS:

    • Operation temperature: 0 °C .. +60 °C
    • Storage temperature -20 °C .. +70 °C
    • Humidity: 0..75%

    PROGRAMS:

    • 50 user-defined

    DIGITAL COMMUNICATION:

    • 1x RS 232
      1x RS 485

    TYPE OF REGULATING DEVICE:

    • No

    KEYBOARD:

    • 14 keys (micro switch)

    MEASUREMENTS RECORDING

    • up to 5000 samples

    REAL TIME CLOCK

    • Yes

    PC SOFTWARE:

    • MPC3

    AUTOSTART

    • Yes

    INPUTS:

    • Analog inputs: 3
      Analog input type 
      PT 100 temperature sensor
      Range: -50 .. 400°C 
      Accuracy: 0.1 °C
    • Binary input: 1
      BINARY INPUT TYPE: 
      0-220 VAC (0-24 VAC)
    • Opto-isolation

    OUTPUTS:

    • Relay outputs: 4
      (Relay output type: Contact 250 V
      Total current of open relays: Iomax = 5 A)

    MISCELLANEOUS:

    • controlling and setting temperature inside a smokehouse, in the range of -10 to 450°C
    • controlling the smokehouse’s temperature increase in the function of chub temperature delta_max = 25.5°C
    • controlling chub temperature in the range of -10 to 25°C
    • Humidity pulsing
    • analysis and notification of emergency conditions
    • manual operation mode

    RELAY CONTACT RATED LOAD

    • Recommended external protection - fuse: 6.3 A
    • Maximum total current (bus) -4A

      CAUTION! Using fuses over 6.3 A is not recommended

    COMPLIANCE WITH STANDARDS:

    • According to directives: 89/336/EEC as amended 
      91/263/EEC
      92/31/EEC
      93/68/EEC
    • PN-EN 60751 +A2:1997
    • PN-92 / E-08106
    • PN-EN 50082-2:1997
    • PN-EN 61000-4-5:1999
    • PN-EN 61000-4-4: 1999
    • PN-EN 61000-4-2: 1999
    • EN 61000-4-11: 1997
    • PN-EN 61000-4-8:1998

    Ask for this product
    Fill in the fields below and submit the form - we will reach you as soon as possible
    Contact data:
    Why you can trust our products?
    We continually develop new technologies

    We continually develop new technologies

    We are constantly developing our products and services in the field of industrial security systems. This practice gave us the position of the industry leader.

    We know your business needs

    We know your business needs

    We work with the best companies in the industry, delivering solutions that effectively meet the needs of transport monitoring.

    We bring long-term savings

    We bring long-term savings

    Advanced solutions for our digital recorders, detectors and controllers will help you optimize your operating costs.