The INDU 41 controller was designed to control the measurement of programmed batches of fluids. It is compatible with most available impulse flow meters. INDU 41 is installed in the control panel. A robust enclosure and high protection rating (IP65 from the buttons’ side) provide for a reliable operation in the most difficult environmental conditions. 100 measuring programs may be stored in the controller’s memory. Batching may be performed with one or two valves: rough batching valve (quick filling) and precise batching valve (slow but precise filling).

The controller as an alarm output. It can contain an external notification device, informing on the completed batching process or generate an alarm when unsealing of valves is detected.

Intended use:
  • fluid batchers

    Technical specifications

    POWER SUPPLY:

    • 230 VAC (optional: 24, 110)

    POWER CONSUMPTION:

    • 4.2 VA

    DIMENSIONS:

    • Mounting hole dimensions: 93x93 mm
    • Installation depth with connections: 68 mm
    • External dimensions of the frame with seal: 144x144 mm

    DISPLAY:

    • LED ½’’ x 2 digits
    • LED ½’’ x 4 digits

    WEIGHT:

    • Controller: 600 g

    ENCLOSURE:

    • Monolithic type Front Panel

    PROTECTION RATING:

    • From the connections’ side: IP 20
    • From the front: IP 65

    TEMPERATURE MEASUREMENT RANGE:

    • No

    OPERATING CONDITIONS:

    • Operating temperature -10 °C .. +55 °C
    • Storage temperature -15 °C .. +60 °C

    PROGRAMS:

    • 100 programs (recipes)

    DIGITAL COMMUNICATION:

    • No

    TYPE OF REGULATING DEVICE:

    • No

    KEYBOARD:

    • 6 keys (micro switch)

    MEASUREMENTS RECORDING

    • Recording set and measured values – ca. 100,000 records.

    REAL TIME CLOCK

    • No

    PC SOFTWARE:

    • Monitor INDU

    AUTOSTART

    • according to RTC with the functionality of programming the controller advance start, up to 10 days

    INPUTS:

    • potential-free digital inputs:
      Control input: contact to GND
      Pulsed input: contact to GND (up to 50 kHz)
      Maximum resistance of closed contact 100 Ω
      Minimum resistance of open contact 10,000 Ω

    OUTPUTS:

    • 2 relay output contact switches (250 VAC/8A)

    MISCELLANEOUS:

    • conditional process termination, programmed from SETUP.

    RELAY CONTACT RATED LOAD

    • Recommended external protection - fuse: 6.3 A
    • Maximum total current (bus) -4A

      CAUTION! Using fuses over 6.3 A is not recommended

    COMPLIANCE WITH STANDARDS:

    • According to directives: 89/336/EEC as amended 
      91/263/EEC
      92/31/EEC
      93/68/EEC
    • PN-EN 60751 +A2:1997
    • PN-92 / E-08106
    • PN-EN 50082-2:1997
    • PN-EN 61000-4-5:1999
    • PN-EN 61000-4-4: 1999
    • PN-EN 61000-4-2: 1999
    • EN 61000-4-11: 1997
    • PN-EN 61000-4-8:1998
    • PN-EN 60584-1:1997
    • PN-89/M-53859

    Ask for this product
    Fill in the fields below and submit the form - we will reach you as soon as possible
    Contact data:
    Why you can trust our products?
    We continually develop new technologies

    We continually develop new technologies

    We are constantly developing our products and services in the field of industrial security systems. This practice gave us the position of the industry leader.

    We know your business needs

    We know your business needs

    We work with the best companies in the industry, delivering solutions that effectively meet the needs of transport monitoring.

    We bring long-term savings

    We bring long-term savings

    Advanced solutions for our digital recorders, detectors and controllers will help you optimize your operating costs.