    Presentation of system components. Control modules



    WRC CPPS-01 power supply unit processor module
    Power supply: 24V AC

    Dimensions:
    Width 150 mm
    Height 45 mm
    Depth 105 mm

    Communication: 1 x RS-485 opto-isolated, 1 x RS-485, bus for communication with other modules (SPI)

    Enclosure: mounted to TS 35 (DIN) rail


    WRC RO-01 relay outputs module
    Power supply: from the WRC system power supply unit

    Dimensions:
    Width 75 mm
    Height 45 mm
    Depth 105 mm

    Outputs: 6 contact relay outputs Imax=2A Umax=250V

    Enclosure: mounted to TS 35 (DIN) rail


    WRC AI-01/6 analog inputs module
    Power supply: from the WRC system power supply unit

    Dimensions:
    Width 75 mm
    Height 45 mm
    Depth 105 mm

    Inputs: 6 inputs for PT100 resistance sensors

    Enclosure: mounted to TS 35 (DIN) rail


    WRC DI-01 digital inputs module
    Power supply: from the WRC system power supply unit

    Dimensions:
    Width 75 mm
    Height 45 mm
    Depth 105 mm

    Inputs: 11 24V inputs (alternating or direct)

    Logical levels:
    - 0-3 V low
    - 10-24 high

    Enclosure: mounted to TS 35 (DIN) rail


    WRC TO-01 transistor outputs module
    Power supply: 12-24V DC

    Dimensions:
    Width 75 mm
    Height 45 mm
    Depth 105 mm

    Outputs: 8 transistor outputs (1A per channel, total current no more than 4A)

    Enclosure: mounted to TS 35 (DIN) rail


    WRC AO-01 analog outputs module
    Power supply: from the WRC system power supply unit

    Dimensions:
    Width 75 mm
    Height 45 mm
    Depth 105 mm

    Outputs: 4 voltage outputs:
    range max.: -10V - +10V DC (accuracy 0.01 V)
    possibility of software ranges, e.g. 0-5 V,

    Enclosure: mounted to TS 35 (DIN) rail


    WRC COM-01 communication processor module
    Power supply: from the WRC system power supply unit

    Dimensions:
    Width 75 mm
    Height 45 mm
    Depth 105 mm

    Digital inputs: 1xRS-485

    Enclosure: mounted to TS 35 (DIN) rail


    Technical specifications
    ZASILANIE:
    • 12-24V AC/DC (typically from modules power supply unit)
    POBÓR MOCY:
    • 6 W
    WYMIARY:
    • Mounting hole dimensions: 142x282 mm
      Installation depth with connections: 48 mm
      External dimensions of the frame with seal: 192x335mm
    WYŚWIETLACZ:
    • 14 ½’’ LED displays
    • 46 LED notification diodes
    • VFD display
    WAGA:
    • Controller: 1250 g
    OBUDOWA :
    • Monolithic type Front Panel
    STOPIEŃ OCHRONY:
    • From the connections’ side: IP 20
    • From the front: IP 65
    POMIAR TEMPERATURY:
    • carried out by modules
    WARUNKI PRACY:
    • Operation temperature: 0 °C .. +60 °C
    • Storage temperature -20 °C .. +70 °C
    • Humidity: 0..75%
    PROGRAMY:
    • 99 technological programs, editable by the user,
      each program consists of 30 cycles,
      each cycle is described by:
      - completed technological step
      - set chamber temperature
      - set chub temperature
      - set humidity
      - set cycle time
    • 1 automatic washing program
    KOMUNIKACJA CYFROWA:
    • 1x RS 485 communication with WRC modules
    • 1x RS 232 barcode scanner
    KLAWIATURA:
    • 30 “CLICK SWITCH” keys
    REJESTRACJA POMIARÓW
    • 1 MB
    ZEGAR CZASU RZECZYWISTEGO
    • Yes
    STANDARDOWO ZAIMPLEMENTOWANE OPROGRAMOWANIE :
    • smoking and scalding chambers
    • ripening chambers
    • climatic chambers
    • shock freezing chambers
    • pasteurisers
    AUTOSTART
    • Yes
    WEJŚCIA :
    • RS485 communication inputs with INDU WRC modules
    INNE:
    • Menu language: Any language with Latin alphabet characters + Cyrillic (defined by the user), language versions change and configuration software included with the panel
    URZĄDZENIE ZEWNĘTRZNE:
    • Hand-held scanner
    OBCIĄŻALNOŚĆ STYKÓW PRZEKAŹNIKOWYCH
    ( MODUŁ WRC RO-01)
    • Recommended external protection - fuse: 6.3 A
    • Maximum total current - 4A
    • Maximum current applied to relay - 4A

      CAUTION! Using fuses over 6.3 A is not recommended

    SPEŁNIA NORMY:
    • According to directives: 89/336/EEC as amended
      91/263/EEC
      92/31/EEC
      93/68/EEC
    • PN-92 / E-08106
    • PN-EN 50082-2:1997
    • PN-EN 61000-4-5:1999
    • PN-EN 61000-4-4: 1999
    • PN-EN 61000-4-2: 1999
    • EN 61000-4-11: 1997
    • PN-EN 61000-4-8:1998

    Ask for this product
    Fill in the fields below and submit the form - we will reach you as soon as possible
    By sending this form you agree to processing of your personal data by Mikster Sp. o.o. in commercial and promotional purposes. Learn more
    Contact data:
    Why you can trust our products?
    We continually develop new technologies

    We continually develop new technologies

    We are constantly developing our products and services in the field of industrial security systems. This practice gave us the position of the industry leader.

    We know your business needs

    We know your business needs

    We work with the best companies in the industry, delivering solutions that effectively meet the needs of transport monitoring.

    We bring long-term savings

    We bring long-term savings

    Advanced solutions for our digital recorders, detectors and controllers will help you optimize your operating costs.